Atipa I-B12S DAS (Direct Attached Storage) Server 1U/12-bay SAS to SAS
The I-B12S features unprecedented space efficiency by providing all advanced RAID functions in a 1U enclosure. Using 2.5-inch disk drives allows twice the number of spindles within the same footprint, and hence is ideal for I/O-intensive applications. The I-B12S supports the capacity expansion with 3 or 4 JBOD enclosures (60 HDD) and the flexibility of attaching both SAS or SATA-II disk drives.
- Dual-active or single controller
- 2.5-inch SAS disk drives
- Four (R1030) or two (G1030) SAS multi-lane host ports
- Hardware RAID5 and RAID6 engine by dedicated ASIC400 chipsets
- EonPath® multipathing software
- Expansion to SAS or SATA JBOD
|
Total Capacity with Expansion
|
Up to 50TB (Max. Capacity Configuration - using 64 SATA HDD in single-controller JBOD)
or
7.2TB (Fault Tolerance Configuration - using 48 SAS HDD in dual-controller JBOD)
|
|
Scalability
|
- Redundant-controller RAID - 3 JBOD
- Single-controller RAID - 4 JBOD
- 1U JBOD - Up to 4 JBOD for a total of 60 HDD
- 2U JBOD - Up to 4 JBOD for a total of 60 HDD
- 3U JBOD - Up to 4 JBOD for a total of 76 HDD
|
|
RAID Levels
|
RAID level 0, 1(0+1), 3, 5, 6, 10, 30, 50, 60; arrays of different RAID levels can co-exist in a configuration.
|
|
Host Connectivity
|
B12S-R1030 - 4 SAS multi-lane SFF-8088
B12S - G1030 - 2 SAS multi-lane SFF-8088
|
|
Drive Connectivity
|
12 SAS HDD via a passive backplane
Drive-side expansion via SAS multi-lane SFF-8088 per controller
|
|
Rackmount Size
|
1U
|
|
Input Voltage
|
115VAC @ 6A
230VAC @ 3A with PFC (auto-switching)
|
|
Frequency
|
47 to 63Hz
|
|
Power Consumption
|
380W (max.)
|
Atipa I-S16S DAS (Direct Attached Storage) Server 3U/16-bay SAS to SAS/SATA
With 4 or 2 SAS wide host ports, each with a 1200MBps bandwidth, the I-S16S aims to succeed SCSI-based arrays in DAS applications. Capacity can be more readily expanded using the SAS wide expansion links by the addition of the I-S16S JBOD. Within the array, reliable SAS drives can be applied for mission-critical operations and the high capacity SATA drives for near-line backup or archival uses.
- SAS to SAS/SATA-II RAID subsystem
- Redundant or single RAID controller
- EonPath® multi-pathing, load-balancing software
- 4 or 2 SAS 4x wide host ports
- Hardware RAID6 engine by dedicated ASIC400 chipsets
- Superior performance w/ uncomplicated connectivityExpansion to SAS or SATA JBOD
- 16 SAS or SATA-II (3Gbps) disk drives
- Expansion to 80TB via a 4x wide expansion port
|
RAID
|
- Hardware RAID5 & RAID6
- Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, NRAID
- RAID Migration
- Configurable stripe size and write policy per array
- Multiple Global, Dedicated, & Enclosure-specific hot-spares
- Intelligent Drive Handling:
- In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
|
|
Host Interface
|
- 4 (S16S-R1030) or 2 (S16S-G1030) SAS wide ports
- 12Gbps bandwidth (half duplex) per port
- Concurrent I/O commands
- Tagged command queuing up to 1024
- Max. command queue up to 1024
- Fault-tolerant host links with the EonPath multi-pathing software
- Included cables:
- S16S-R1030 – 2x SFF-8088-to-SFF-8470 120cm cables
|
|
Drive Interface
|
- 16 3.0Gbps SAS/SATA-II, hot-swappable drive trays
- Accommodates 1-inch pitch, 3.5-inch SAS or SATA-II (3Gbps) disk drives
- S.M.A.R.T. and NCQ support
- Automatic bad-sector reassignment
- Dedicated bandwidth to each connected drive
- In-band enclosure service through the expansion links from expansion enclosures
- Path redundancy to disk drives via edge expanders and expanders on JBOD controllers through separate SAS domains
- MUX kits with port selectors for dual-controller access to SATA drives
|
|
System Components
|
- High density, smartly managed 3U enclosure
- Dual redundant or single RAID controller
- One DIMM module with capacities from 512MB to 2GB
- Redundant, hot-swappable 530W power supply units
- Redundant, dual-speed cooling modules
- Sixteen (16), hot-swappable drive trays
- Two (2) forearm handles
- Li-Ion battery backup unit (BBU), life expectancy and charge level aware
|
|
Management
|
- COM1 serial port for local access to firmware-embedded utility
- COM2 for UPS connection
- Automated cache flush and caching mode operation per enclosure status
- GUI, Telnet, and SSH system monitoring via Ethernet
- Java-based SANWatch software with Snapshot protection
- Firmware-embedded manager via RS-232C (audio jack) that is platform independent
- Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
- LCD keypad panel for monitoring and access to all configuration options
- Variable logical drive options per DIMM size
- Module status LED indicators:
- Two (2) per drive tray
- Seven (7) per controller module
- One (1) per power supply unit
- One (1) per BBU module
- Two (2) per cooling module
- Presence detection & thermal sensors via I2C bus
|
|
Power Supply Module
|
Redundant hot-swappable power supplies with PFC
|
|
Cooling Module
|
Redundant dual-thermal-fan cooling modules
|
|